Description

On CIMug Prag Margaret Goodrich presented on the CIM University "03-61968-9 Meter Reading and Control.pdf". On Page 13 an example of an EndDeviceEvent (<ns1:EndDeviceEventType ref=“3.26.0.85”/>).
This is no good xml modelling.

Proposed Resolution

<ns1:EndDeviceEventType EndDeviceType="3" EndDeviceDomain="26" EndDeviceSubdomain="0" EndDeviceEventorAction="85"/> would be much better and more xml conform.